The premier power system makes outages obsolete, utilizing an AC-DC-AC conversion process to eliminate surges, to meet the demands of both AC and DC equipment, and to provide nonstop power. Its heart is the Automatic Transfer Control Logic system (ATCL) that monitors power throughout the system to draw only from the most reliable sources.

  • UPS modules

  • DC Power Station

  • Automatic Transfer Control Logic System

  • Transformer

  • Diesel Generator

  • Battery Backup System

The power backups are utilized in the following order:

1) Commercial utility underground conduits
2) Two-hour battery backup (industry standard only 15 minutes)
3) Diesel generator with full-load capability and 18 hr. fuel supply.

In addition, the system features:
  • Parallel redundant UPS module
  • Redundant primary 480V feeders
  • Split switchboard with draw-out tie-breaker
  • Redundant 500KVA K13 transformers
  • 48V DC power plant with separate batteries and A+B bus for redundancy
  • Dual-fed secondary switchboard and critical load distribution boards
  • Maintenance bypass feeder with dedicated 500 KVA K13 transformer
  • Dedicated 20 amp circuits with #10AWG (30 amp) wiring to rack plug strips, including dedicated neutrals feeding server racks


We appreciate that both equipment and data security are vital to our clients. With that in mind, comprehensive security systems include visitation access lists, security cameras, and dedicated Ethernet segments.

Seven days a week, around the clock, security personnel superintend the Operations Center lobby. A digital surveillance camera monitors all sections of the Network Center and all installed equipment.


The Operations Center maintains a constant temperature of 68¼F, plus or minus 2¼F, with humidity at a constant of 45%. This facility has 200 tons of total cooling capacity, more than enough to maintain these temperature and humidity levels.

The Jacksonville, FL facility incorporates features to maximize equipment performance. The floors consist of 6-inch concrete slabs with natural anti-static properties balanced by embedded carbon filaments, grounded by copper strips. Cables are trayed above the racks and color-coded for simplified maintenance.


All client equipment is protected by two fire fighting systems, a Fire Master 200 (FM 200) fire suppression system and a pre-action dry pipe sprinkler system. The FM 200 utilizes heptaflouropropane gas, the environmentally friendly answer to Halon that is both sate and non-corrosive to electrical equipment. This gas deploys after a 30 second countdown and slows the fire by chemically preventing combustion.


The dry-pipe system backs up the FM 200 by being connected to a VESDA smoke detection system. Only a combination of 2 "events" (melting of sprinkler valve seal and the FM200 having already released the gas) allows water to fill the pipes and be sprayed only through the open sprinkler heads. In most cases, the remaining facility stays fully operational.

   
   
 